OFF GAS DETECTOR

Technical Details

 E2673 and E2673A are specifically designed for battery-based applications. Applications include battery energy storage systems (BESS), data centers and UPS rooms, EV charging stations, battery manufacturing facilities.

The device was developed using long-life maintenance free sensing technologies: electrochemical for Carbon monoxide, thermal conductivity for Hydrogen, MOS for Volatile Organic Compounds.


RS485 digital interface with industry standard Modbus RTU protocol

Three SPST relays rated at 300mA for 30 VDC for warning, alarm and fault reporting

Power input - 12...36 VDC

Two Evikon off-gassing detectors E2673 and E2673A with specifications.

DETECTION PARAMETERS

HYDROGEN

VOLATILE ORGANIC COMPOUNDS

VOLATILE ORGANIC COMPOUNDS

  • Range - 0 .. 100% LEL
  • Resolution - 0.02% LEL
  • Accuracy - < 3 %LEL H2 @ 0…50 %LEL
  • Sensor - Thermal Conductivity
  • Stability - > 97 % for 5 years

VOLATILE ORGANIC COMPOUNDS

VOLATILE ORGANIC COMPOUNDS

VOLATILE ORGANIC COMPOUNDS

  • Range - 0 .. 500 VOC Index
  • Resolution - 1.0 Index
  • Warm Up - < 1 min
  • Sensor - MOS
  • Calibration Free

CARBON MONOXIDE

VOLATILE ORGANIC COMPOUNDS

CARBON MONOXIDE

  • Range - 0 .. 300 PPM
  • Resolution - 1 ppm
  • Warm Up - < 1 min
  • Sensor - Electrochemical
  • Stability - > 97 % per year

TEMPERATURE

TEMPERATURE

CARBON MONOXIDE

  • Range - -40…+85 °C
  • Resolution - 0.1 °C
  • Accuracy - < 0,3 °C
  • Calibration Free

HUMIDITY

TEMPERATURE

HUMIDITY

  • Range - 0…100 %RH
  • Resolution - 0.1 %RH
  • Accuracy - < 2 %RH
  • Calibration Free

Fire Safety Solutions by Ignix

Sign up for updates on latest developments in BESS fire safety

Copyright © 2026 Incenditech Pvt Ltd - All Rights Reserved.

  • About Us
  • IGNIX FPDS
  • IGNIX SHIELD
  • IGNIX SENTRY
  • IGNIX SENSE
  • IGNIX GUARD
  • OFF GAS DETECTION
  • Contact Us

Powered by

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

Accept